 APPLICATION: MEASURING THE TOTAL VOLUME OF COLD POTABLE WATER PASSING THROUGH THE METER,IT'S SUITABLE FOR DOMESTIC USE.   WORKING CONDITIONS: * THE MAX.ADMISSIBLE WATER PRESSURE: 1.6MPa * WATER TEMP: UP TO 50℃   SPECIALITY: * LARGE MEASURING RANGE, HIGH FLOW ACCURACY. * PLASTIC BODY, STEADY ERROR CURVE. * LONG LIFE OF SERVICE * RELIABLE OPERATION. * MAGNETIC SHIELD PROTECTION. * NEGLIGIBLE HEAD LOSS AT WORKING FLOW – RATES. * SEALED & VACCUMIZED REGISTER WITHOUT ANY CONDENSATION PROBLEM. Maximum permissible error:
 Between qt (included) and qs is ±2%; Between qmin and qt (excluded) is ±5%. NOTE: The technical data conform to ISO4064 standard, class B.
 FLOW-ERROR CURVE
  SPECIFICATION AND OVERALL DIMENSIONS
  
| Description | Unit | Hydraulic data and dimensions |  
| Nominal size  | mm | 15 | 20 |  
| inch | 1/2 | 3/4 |  
| Overload flow-rate (qs) | m3/h | 3 | 5 |  
| Permanent flow-rate (qp) | m3/h | 1.5 | 2.5 |  
| Transitional flow-rate (qt) | l/h | 120 | 200 |  
| Minimum flow-rate (qmin) | l/h | 30 | 50 |  
| Min. reading  | l | 0.05 | 0.05 |  
| Max. reading  | m3 | 99999.9999 | 99999.9999 |  
| Nominal pressure  | MPa | 1.6 | 1.6 |  
| ΔP at the qs | MPa | 0.06 | 0.08 |  
| L | mm | 165 | 190 |  
| 190 |  
| I | mm | 245 | 290 |  
| 290 |  
| H  | mm | 122 | 122 |  
| h | mm | 39 | 39 |  
| B  | mm | 100 | 100 |  
| weight | Without connections | Kg | 0.58 | 0.62 |  
| 0.60 |  
| With connections | 0.63 | 0.68 |  
| 0.65 |  OVERALL DIMENSIONS                                                              PRESSURE LOSS CURVE
  |